Skip to main content

 11RL | pdb_000011rl

CryoEM structure of the human origin recognition complex with DNA and CDC6 protein


ELECTRON MICROSCOPY

Starting Model(s)

Initial Refinement Model(s)
TypeSourceAccession CodeDetails
experimental modelPDB 7JPS 

Refinement

RMS Deviations
KeyRefinement Restraint Deviation
f_dihedral_angle_d17.241
f_angle_d0.461
f_chiral_restr0.037
f_plane_restr0.004
f_bond_d0.002
Sample
Human ORC subunits (1-5) and Human CDC6 protein complex with 60bp DNA
Specimen Preparation
Sample Aggregation StatePARTICLE
Vitrification InstrumentLEICA EM GP
Cryogen NameETHANE
Sample Vitrification DetailsThe sample was applied to a glow-discharged Quantifoil R 0.6/1 300 mesh copper grid (previously washed with ethyl acetate), incubated for 10 seconds, ...The sample was applied to a glow-discharged Quantifoil R 0.6/1 300 mesh copper grid (previously washed with ethyl acetate), incubated for 10 seconds, blotted for 3 seconds, and plunged into liquid ethane using a Leica Automatic Plunge Freezer EM GP2.
3D Reconstruction
Reconstruction MethodSINGLE PARTICLE
Number of Particles130819
Reported Resolution (Å)2.8
Resolution MethodFSC 0.5 CUT-OFF
Other Details
Refinement Type
Symmetry TypePOINT
Map-Model Fitting and Refinement
Id1 (7JPS)
Refinement SpaceREAL
Refinement ProtocolFLEXIBLE FIT
Refinement Target
Overall B Value
Fitting Procedure
DetailsInitial local fitting was done using Chimera, and then Coot was used for flexible fitting and model building.
Data Acquisition
Detector TypeGATAN K3 BIOQUANTUM (6k x 4k)
Electron Dose (electrons/Å**2)43.2
Imaging Experiment1
Date of Experiment
Temperature (Kelvin)
Microscope ModelTFS KRIOS
Minimum Defocus (nm)600
Maximum Defocus (nm)2200
Minimum Tilt Angle (degrees)
Maximum Tilt Angle (degrees)
Nominal CS
Imaging ModeBRIGHT FIELD
Specimen Holder ModelFEI TITAN KRIOS AUTOGRID HOLDER
Nominal Magnification105000
Calibrated Magnification
SourceFIELD EMISSION GUN
Acceleration Voltage (kV)300
Imaging Details
EM Software
TaskSoftware PackageVersion
PARTICLE SELECTIONWarp1.0.9
PARTICLE SELECTIONcryoSPARC4.7.1
IMAGE ACQUISITIONWarp1.0.9
IMAGE ACQUISITIONEPU
CTF CORRECTIONWarp1.0.9
MODEL FITTINGCoot0.9.8.95
INITIAL EULER ASSIGNMENTcryoSPARC4.7.1
FINAL EULER ASSIGNMENTcryoSPARC4.7.1
CLASSIFICATIONcryoSPARC4.7.1
RECONSTRUCTIONcryoSPARC4.7.1
MODEL REFINEMENTPHENIX1.21.2_5419
Image Processing
CTF Correction TypeCTF Correction DetailsNumber of Particles SelectedParticle Selection Details
PHASE FLIPPING AND AMPLITUDE CORRECTIONCTF correction was done first in WARP during exposure/micrograph pre-processing, and re-corrected during the final refinements/reconstruction of the map in cryoSPARCParticle picking used a BoxNet pre-trained neural network implemented in TensorFlow, with a particle diameter of 180 angstrom and a threshold score of 0.5