5NP7

CryoEM structure of Human Rad51 on single-stranded DNA to 4.2A resolution.


ELECTRON MICROSCOPY

Refinement

RMS Deviations
KeyRefinement Restraint Deviation
r_long_range_B_refined44.967
r_dihedral_angle_2_deg37.024
r_dihedral_angle_3_deg23.006
r_mcangle_it19.492
r_dihedral_angle_4_deg18.909
r_scbond_it15.798
r_mcbond_it11.5
r_dihedral_angle_1_deg6.724
r_angle_refined_deg2.647
r_chiral_restr0.21
RMS Deviations
KeyRefinement Restraint Deviation
r_long_range_B_refined44.967
r_dihedral_angle_2_deg37.024
r_dihedral_angle_3_deg23.006
r_mcangle_it19.492
r_dihedral_angle_4_deg18.909
r_scbond_it15.798
r_mcbond_it11.5
r_dihedral_angle_1_deg6.724
r_angle_refined_deg2.647
r_chiral_restr0.21
r_bond_refined_d0.019
r_gen_planes_refined0.011
r_bond_other_d
r_angle_other_deg
r_gen_planes_other
r_nbd_refined
r_nbd_other
r_nbtor_refined
r_nbtor_other
r_xyhbond_nbd_refined
r_xyhbond_nbd_other
r_metal_ion_refined
r_metal_ion_other
r_symmetry_vdw_refined
r_symmetry_vdw_other
r_symmetry_hbond_refined
r_symmetry_hbond_other
r_symmetry_metal_ion_refined
r_symmetry_metal_ion_other
r_mcbond_other
r_mcangle_other
r_scbond_other
r_scangle_it
r_scangle_other
r_long_range_B_other
r_rigid_bond_restr
r_sphericity_free
r_sphericity_bonded
Sample
Helical filament of HRAD51 on single-stranded DNA with AMPPNP
Specimen Preparation
Sample Aggregation StateHELICAL ARRAY
Vitrification Instrument
Cryogen NameNITROGEN
Sample Vitrification Details
3D Reconstruction
Reconstruction MethodHELICAL
Number of Particles60000
Reported Resolution (Å)4.2
Resolution MethodFSC 0.143 CUT-OFF
Other DetailsHelical segments were divided in half, not drawn randomly or odd/even as this would result in some segments from the same filament in both half models ...Helical segments were divided in half, not drawn randomly or odd/even as this would result in some segments from the same filament in both half models. Thus, it is strictly not gold-standard.
Refinement Type
Symmetry TypeHELICAL
Axial SymmetryC1
Axial Rise16
Angular Rotation56.2
Map-Model Fitting and Refinement
Id1
Refinement SpaceRECIPROCAL
Refinement ProtocolFLEXIBLE FIT
Refinement TargetMaximum likelihood
Overall B Value94.574
Fitting Procedure
DetailsBackbone fitting is good but many of the sidechains cannot be relied on as the map resolution was insufficient.
Data Acquisition
Detector TypeFEI FALCON II (4k x 4k)
Electron Dose (electrons/Å**2)20
Imaging Experiment1
Date of Experiment
Temperature (Kelvin)
Microscope ModelFEI TITAN KRIOS
Minimum Defocus (nm)2000
Maximum Defocus (nm)
Minimum Tilt Angle (degrees)
Maximum Tilt Angle (degrees)
Nominal CS2.7
Imaging ModeBRIGHT FIELD
Specimen Holder ModelFEI TITAN KRIOS AUTOGRID HOLDER
Nominal Magnification59000
Calibrated Magnification104477
SourceFIELD EMISSION GUN
Acceleration Voltage (kV)300
Imaging Details
EM Software
TaskSoftware PackageVersion
PARTICLE SELECTIONXimdisp
IMAGE ACQUISITIONEPU
CTF CORRECTIONGctf
MODEL FITTINGCoot
CLASSIFICATIONRELION1.4
RECONSTRUCTIONRELION1.4
MODEL REFINEMENTREFMAC
Image Processing
CTF Correction TypeCTF Correction DetailsNumber of Particles SelectedParticle Selection Details
NONEper segment70000