5U70

Chicken Slo2.2 in an open conformation vitrified in the presence of 300 mM NaCl


ELECTRON MICROSCOPY

Refinement

RMS Deviations
KeyRefinement Restraint Deviation
r_dihedral_angle_2_deg29.964
r_long_range_B_refined15.497
r_long_range_B_other15.497
r_dihedral_angle_3_deg12.276
r_scangle_other10.958
r_mcangle_it9.095
r_mcangle_other9.095
r_dihedral_angle_4_deg8.856
r_scbond_it6.091
r_scbond_other6.09
RMS Deviations
KeyRefinement Restraint Deviation
r_dihedral_angle_2_deg29.964
r_long_range_B_refined15.497
r_long_range_B_other15.497
r_dihedral_angle_3_deg12.276
r_scangle_other10.958
r_mcangle_it9.095
r_mcangle_other9.095
r_dihedral_angle_4_deg8.856
r_scbond_it6.091
r_scbond_other6.09
r_mcbond_it5.4
r_mcbond_other5.395
r_dihedral_angle_1_deg5.028
r_angle_refined_deg0.91
r_angle_other_deg0.794
r_chiral_restr0.05
r_bond_refined_d0.006
r_gen_planes_refined0.003
r_bond_other_d0.001
r_gen_planes_other0.001
r_nbd_refined
r_nbd_other
r_nbtor_refined
r_nbtor_other
r_xyhbond_nbd_refined
r_xyhbond_nbd_other
r_metal_ion_refined
r_metal_ion_other
r_symmetry_vdw_refined
r_symmetry_vdw_other
r_symmetry_hbond_refined
r_symmetry_hbond_other
r_symmetry_metal_ion_refined
r_symmetry_metal_ion_other
r_scangle_it
r_rigid_bond_restr
r_sphericity_free
r_sphericity_bonded
Sample
Chicken Slo2.2 in open conformation
Specimen Preparation
Sample Aggregation StatePARTICLE
Vitrification InstrumentFEI VITROBOT MARK IV
Cryogen NameETHANE
Sample Vitrification Details
3D Reconstruction
Reconstruction MethodSINGLE PARTICLE
Number of Particles130000
Reported Resolution (Å)3.76
Resolution MethodFSC 0.143 CUT-OFF
Other Details
Refinement Type
Symmetry TypePOINT
Point SymmetryC4
Map-Model Fitting and Refinement
Id1
Refinement Space
Refinement ProtocolAB INITIO MODEL
Refinement Target
Overall B Value
Fitting Procedure
Details
Data Acquisition
Detector TypeGATAN K2 SUMMIT (4k x 4k)
Electron Dose (electrons/Å**2)59
Imaging Experiment1
Date of Experiment
Temperature (Kelvin)
Microscope ModelFEI TITAN KRIOS
Minimum Defocus (nm)1000
Maximum Defocus (nm)3000
Minimum Tilt Angle (degrees)
Maximum Tilt Angle (degrees)
Nominal CS2.7
Imaging ModeBRIGHT FIELD
Specimen Holder Model
Nominal Magnification
Calibrated Magnification
SourceFIELD EMISSION GUN
Acceleration Voltage (kV)300
Imaging Details
EM Software
TaskSoftware PackageVersion
IMAGE ACQUISITIONSerialEM
CTF CORRECTIONCTFFIND44.0.16
MODEL REFINEMENTPHENIX
MODEL REFINEMENTREFMAC
INITIAL EULER ASSIGNMENTRELION2.0
FINAL EULER ASSIGNMENTFREALIGN
CLASSIFICATIONRELION2.0
RECONSTRUCTIONFREALIGN
Image Processing
CTF Correction TypeCTF Correction DetailsNumber of Particles SelectedParticle Selection Details
PHASE FLIPPING AND AMPLITUDE CORRECTION160000Manual particle selection in RELION