ELECTRON MICROSCOPY
Sample |
---|
human BK channel reconstituted into liposomes |
Specimen Preparation | |
---|---|
Sample Aggregation State | PARTICLE |
Vitrification Instrument | FEI VITROBOT MARK IV |
Cryogen Name | ETHANE |
Sample Vitrification Details | BK proteoliposomes were applied onto a glow-discharged perforated carbon grid (CFlat R2/2, EMS), and incubated for 5-10 min In an FEI Vitrobot Mark IV ... |
3D Reconstruction | |
---|---|
Reconstruction Method | SINGLE PARTICLE |
Number of Particles | 122456 |
Reported Resolution (Å) | 3.5 |
Resolution Method | FSC 0.143 CUT-OFF |
Other Details | |
Refinement Type | |
Symmetry Type | POINT |
Point Symmetry | C2 |
Map-Model Fitting and Refinement | |||||
---|---|---|---|---|---|
Id | 1 | ||||
Refinement Space | REAL | ||||
Refinement Protocol | FLEXIBLE FIT | ||||
Refinement Target | |||||
Overall B Value | |||||
Fitting Procedure | |||||
Details |
Data Acquisition | |||||||||
---|---|---|---|---|---|---|---|---|---|
Detector Type | GATAN K2 SUMMIT (4k x 4k) | ||||||||
Electron Dose (electrons/Å**2) | 60 |
Imaging Experiment | 1 |
---|---|
Date of Experiment | |
Temperature (Kelvin) | |
Microscope Model | FEI TITAN KRIOS |
Minimum Defocus (nm) | 852 |
Maximum Defocus (nm) | 4000 |
Minimum Tilt Angle (degrees) | |
Maximum Tilt Angle (degrees) | |
Nominal CS | 2.7 |
Imaging Mode | BRIGHT FIELD |
Specimen Holder Model | FEI TITAN KRIOS AUTOGRID HOLDER |
Nominal Magnification | 130000 |
Calibrated Magnification | |
Source | FIELD EMISSION GUN |
Acceleration Voltage (kV) | 300 |
Imaging Details | The Coma free alignment was performed using Auto-CTF software from FEI. |
EM Software | ||
---|---|---|
Task | Software Package | Version |
PARTICLE SELECTION | RELION | 2.1 |
PARTICLE SELECTION | MATLAB | R2018a |
IMAGE ACQUISITION | Leginon | 3.3 |
CTF CORRECTION | CTFFIND | 4 |
CTF CORRECTION | Gctf | |
INITIAL EULER ASSIGNMENT | RELION | 2.1 |
FINAL EULER ASSIGNMENT | RELION | 2.1 |
CLASSIFICATION | RELION | 2.1 |
RECONSTRUCTION | RELION | 2.1 |
Image Processing | ||||
---|---|---|---|---|
CTF Correction Type | CTF Correction Details | Number of Particles Selected | Particle Selection Details | |
PHASE FLIPPING AND AMPLITUDE CORRECTION | CTF full correction was performed following RELION 3D reconstruction | 275295 | Approximately 4,800 particles from 350 micrographs were interactively selected and classified using RELION. Ten representative classes were selected as the templates for automated particle picking using RELION. The automated picked particles were screened using homemade MATLAB (MathWorks) programs to exclude particles more than 80 A away from any liposome, which resulted in 275,295 particles from 2,786 micrographs. |