GTPgammaS Tube decorated with kinesin
Refinement RMS Deviations Key Refinement Restraint Deviation f_dihedral_angle_d 10.056 f_angle_d 1.84 f_chiral_restr 0.075 f_plane_restr 0.015 f_bond_d 0.009
Sample GTPgammaS-tube decorated with kinesin
Specimen Preparation Sample Aggregation State HELICAL ARRAY Vitrification Instrument FEI VITROBOT MARK IV Cryogen Name ETHANE Sample Vitrification Details
3D Reconstruction Reconstruction Method HELICAL Number of Particles 74919 Reported Resolution (Å) 6.8 Resolution Method FSC 0.143 CUT-OFF Other Details Refinement Type Symmetry Type HELICAL Axial Symmetry C1 Axial Rise 17.92 Angular Rotation 22.71
Map-Model Fitting and Refinement Id 1 Refinement Space Refinement Protocol Refinement Target Overall B Value Fitting Procedure Details
Data Acquisition Detector Type GATAN K2 SUMMIT (4k x 4k) Electron Dose (electrons/Å**2) 50
Imaging Experiment 1 Date of Experiment Temperature (Kelvin) Microscope Model FEI TITAN KRIOS Minimum Defocus (nm) 500 Maximum Defocus (nm) 2500 Minimum Tilt Angle (degrees) Maximum Tilt Angle (degrees) Nominal CS Imaging Mode BRIGHT FIELD Specimen Holder Model Nominal Magnification Calibrated Magnification Source FIELD EMISSION GUN Acceleration Voltage (kV) 300 Imaging Details
EM Software Task Software Package Version MODEL REFINEMENT PHENIX
Image Processing CTF Correction Type CTF Correction Details Number of Particles Selected Particle Selection Details NONE