☰ Navigation Tabs
Active state homomeric GluA1 AMPA receptor in complex with TARP gamma 3
Refinement RMS Deviations Key Refinement Restraint Deviation r_long_range_B_refined 26.583 r_long_range_B_other 26.583 r_dihedral_angle_3_deg 17.212 r_scangle_other 16.716 r_mcangle_it 15.09 r_mcangle_other 15.089 r_scbond_it 10.128 r_scbond_other 10.128 r_mcbond_it 9.39 r_mcbond_other 9.39
Show All KeysRMS Deviations Key Refinement Restraint Deviation r_long_range_B_refined 26.583 r_long_range_B_other 26.583 r_dihedral_angle_3_deg 17.212 r_scangle_other 16.716 r_mcangle_it 15.09 r_mcangle_other 15.089 r_scbond_it 10.128 r_scbond_other 10.128 r_mcbond_it 9.39 r_mcbond_other 9.39 r_dihedral_angle_1_deg 5.658 r_dihedral_angle_2_deg 4.557 r_angle_refined_deg 1.414 r_angle_other_deg 0.624 r_chiral_restr 0.087 r_gen_planes_refined 0.007 r_bond_refined_d 0.006 r_gen_planes_other 0.003 r_bond_other_d r_dihedral_angle_4_deg r_nbd_refined r_nbd_other r_nbtor_refined r_nbtor_other r_xyhbond_nbd_refined r_xyhbond_nbd_other r_metal_ion_refined r_metal_ion_other r_symmetry_vdw_refined r_symmetry_vdw_other r_symmetry_hbond_refined r_symmetry_hbond_other r_symmetry_metal_ion_refined r_symmetry_metal_ion_other r_scangle_it r_rigid_bond_restr r_sphericity_free r_sphericity_bonded
Hide All Keys
Sample Homomeric GluA1 AMPA receptor in complex with TARP gamma 3
Specimen Preparation Sample Aggregation State PARTICLE Vitrification Instrument Cryogen Name ETHANE Sample Vitrification Details
3D Reconstruction Reconstruction Method SINGLE PARTICLE Number of Particles 247485 Reported Resolution (Å) 2.9 Resolution Method FSC 0.143 CUT-OFF Other Details Refinement Type Symmetry Type POINT Point Symmetry C1
Map-Model Fitting and Refinement Id 1 Refinement Space RECIPROCAL Refinement Protocol Refinement Target Overall B Value Fitting Procedure Details Servalcat
Data Acquisition Detector Type GATAN K3 BIOQUANTUM (6k x 4k) Electron Dose (electrons/Å**2) 50
Imaging Experiment 1 Date of Experiment Temperature (Kelvin) Microscope Model TFS KRIOS Minimum Defocus (nm) 1400 Maximum Defocus (nm) 2400 Minimum Tilt Angle (degrees) Maximum Tilt Angle (degrees) Nominal CS Imaging Mode BRIGHT FIELD Specimen Holder Model Nominal Magnification Calibrated Magnification Source FIELD EMISSION GUN Acceleration Voltage (kV) 300 Imaging Details
EM Software Task Software Package Version MODEL REFINEMENT REFMAC
Image Processing CTF Correction Type CTF Correction Details Number of Particles Selected Particle Selection Details PHASE FLIPPING AND AMPLITUDE CORRECTION