☰ Navigation Tabs
ATP-bound mtHsp60 V72I focus
Refinement RMS Deviations Key Refinement Restraint Deviation f_dihedral_angle_d 4.36 f_angle_d 0.438 f_chiral_restr 0.041 f_plane_restr 0.003 f_bond_d 0.002
Specimen Preparation Sample Aggregation State PARTICLE Vitrification Instrument FEI VITROBOT MARK IV Cryogen Name ETHANE Sample Vitrification Details Wait time 10 sec, blot time 3 sec, blot force 0
3D Reconstruction Reconstruction Method SINGLE PARTICLE Number of Particles 137145 Reported Resolution (Å) 3.2 Resolution Method FSC 0.143 CUT-OFF Other Details Refinement Type Symmetry Type POINT Point Symmetry C1
Map-Model Fitting and Refinement Id 1 Refinement Space Refinement Protocol FLEXIBLE FIT Refinement Target Overall B Value Fitting Procedure Details
Data Acquisition Detector Type GATAN K2 SUMMIT (4k x 4k) Electron Dose (electrons/Å**2) 66
Imaging Experiment 1 Date of Experiment Temperature (Kelvin) Microscope Model TFS GLACIOS Minimum Defocus (nm) 1000 Maximum Defocus (nm) 2000 Minimum Tilt Angle (degrees) Maximum Tilt Angle (degrees) Nominal CS 2.7 Imaging Mode BRIGHT FIELD Specimen Holder Model FEI TITAN KRIOS AUTOGRID HOLDER Nominal Magnification 45000 Calibrated Magnification 53937 Source FIELD EMISSION GUN Acceleration Voltage (kV) 200 Imaging Details
EM Software Task Software Package Version PARTICLE SELECTION cryoSPARC IMAGE ACQUISITION SerialEM CTF CORRECTION CTFFIND INITIAL EULER ASSIGNMENT cryoSPARC FINAL EULER ASSIGNMENT cryoSPARC RECONSTRUCTION cryoSPARC MODEL REFINEMENT PHENIX
Image Processing CTF Correction Type CTF Correction Details Number of Particles Selected Particle Selection Details PHASE FLIPPING AND AMPLITUDE CORRECTION