8P6P
Mycoplasma pneumoniae small ribosomal subunit in chloramphenicol-treated cells
ELECTRON MICROSCOPY
Refinement
RMS Deviations | |
---|---|
Key | Refinement Restraint Deviation |
f_dihedral_angle_d | 13.87 |
f_angle_d | 0.564 |
f_chiral_restr | 0.032 |
f_plane_restr | 0.006 |
f_bond_d | 0.003 |
Sample |
---|
Mycoplasma pneumoniae M129 cells treated with chloramphenicol |
Specimen Preparation | |
---|---|
Sample Aggregation State | CELL |
Vitrification Instrument | HOMEMADE PLUNGER |
Cryogen Name | ETHANE-PROPANE |
Sample Vitrification Details | Back-side blotting for 2-3 seconds before plunging using a manual plunger without an environmental control chamber. |
3D Reconstruction | |
---|---|
Reconstruction Method | SUBTOMOGRAM AVERAGING |
Number of Particles | 30774 |
Reported Resolution (Å) | 3.2 |
Resolution Method | FSC 0.143 CUT-OFF |
Other Details | half maps from Warp/M |
Refinement Type | |
Symmetry Type | POINT |
Point Symmetry | C1 |
Map-Model Fitting and Refinement | |||||
---|---|---|---|---|---|
Id | 1 (7OOC, 7OOD) | ||||
Refinement Space | REAL | ||||
Refinement Protocol | RIGID BODY FIT | ||||
Refinement Target | Cross-correlation coefficient | ||||
Overall B Value | |||||
Fitting Procedure | |||||
Details |
Data Acquisition | |||||||||
---|---|---|---|---|---|---|---|---|---|
Detector Type | GATAN K3 BIOQUANTUM (6k x 4k) | ||||||||
Electron Dose (electrons/Å**2) | 3.34 |
Imaging Experiment | 1 |
---|---|
Date of Experiment | |
Temperature (Kelvin) | |
Microscope Model | FEI TITAN KRIOS |
Minimum Defocus (nm) | 1000 |
Maximum Defocus (nm) | 3250 |
Minimum Tilt Angle (degrees) | |
Maximum Tilt Angle (degrees) | |
Nominal CS | 2.7 |
Imaging Mode | BRIGHT FIELD |
Specimen Holder Model | FEI TITAN KRIOS AUTOGRID HOLDER |
Nominal Magnification | 64000 |
Calibrated Magnification | |
Source | FIELD EMISSION GUN |
Acceleration Voltage (kV) | 300 |
Imaging Details |
EM Software | ||
---|---|---|
Task | Software Package | Version |
VOLUME SELECTION | PyTom | 0.9.7.1 |
VOLUME SELECTION | Warp | 1.0.9 |
IMAGE ACQUISITION | SerialEM | 3.9 |
CTF CORRECTION | Warp | 1.0.9 |
MODEL FITTING | Coot | 0.9.8.5 |
FINAL EULER ASSIGNMENT | RELION | 3.0.8 |
FINAL EULER ASSIGNMENT | Warp | 1.0.9 |
CLASSIFICATION | RELION | 3.0.8 |
RECONSTRUCTION | Warp | 1.0.9 |
MODEL REFINEMENT | PHENIX | 1.20.1_4487 |
Image Processing | ||||
---|---|---|---|---|
CTF Correction Type | CTF Correction Details | Number of Particles Selected | Particle Selection Details | |
PHASE FLIPPING AND AMPLITUDE CORRECTION | CTF estimation and 3D CTF correction are done in Warp |