Find PDB structures and Computed Structure Models (CSM) by combining queries from tools in this suite: Attribute Search, Sequence Similarity, Sequence Motif, 3D Similarity, and 3D Motif with 'AND' logic.
Cryo-EM structure of the pentameric human MRS2 magnesium channel under Mg2+-free condition at an average resolution of 3.3 A, filtered to local resolution, C5
Specimen Preparation
Sample Aggregation State
PARTICLE
Vitrification Instrument
LEICA EM GP
Cryogen Name
ETHANE
Sample Vitrification Details
400-mesh R1.2/1.3 Cu grids (Quantifoil) were made hydrophilic by glow discharging for 60 seconds with a current of 15 mA in a PELCO easiGlow system. T ...
400-mesh R1.2/1.3 Cu grids (Quantifoil) were made hydrophilic by glow discharging for 60 seconds with a current of 15 mA in a PELCO easiGlow system. The cryo grids were produced using a Leica EM GP2 (Leica). The chamber was kept at 4 C and set to 95% humidity. 3 microliter sample at 0.5 mg/ml was applied to a glow-discharged holey grid, blotted for 6 s, and plunge frozen into liquid ethane and stored in liquid nitrogen.
3D Reconstruction
Reconstruction Method
SINGLE PARTICLE
Number of Particles
1744117
Reported Resolution (Å)
3.3
Resolution Method
FSC 0.143 CUT-OFF
Other Details
Final non-uniform refinement by using 1,744,117 particles yielded maps at 3.3 A (with C5 symmetry applied) and 3.6 A (with C1 symmetry applied) acco ...
Final non-uniform refinement by using 1,744,117 particles yielded maps at 3.3 A (with C5 symmetry applied) and 3.6 A (with C1 symmetry applied) according to gold-standard FSC = 0.143 criterion.
Refinement Type
Symmetry Type
POINT
Point Symmetry
C5
Map-Model Fitting and Refinement
Id
1 (8TUL)
2 (8TUL)
Refinement Space
REAL
REAL
Refinement Protocol
RIGID BODY FIT
FLEXIBLE FIT
Refinement Target
Overall B Value
141
141
Fitting Procedure
Details
For the MRS2-EDTA structures, models were generated from multiple rounds of manual refinement and real-space refinements with the final model of MRS2- ...
For the MRS2-EDTA structures, models were generated from multiple rounds of manual refinement and real-space refinements with the final model of MRS2-Mg2+ as initial model.
Data Acquisition
Detector Type
GATAN K3 BIOQUANTUM (6k x 4k)
Electron Dose (electrons/Å**2)
50
Imaging Experiment
1
Date of Experiment
Temperature (Kelvin)
Microscope Model
FEI TITAN KRIOS
Minimum Defocus (nm)
700
Maximum Defocus (nm)
2000
Minimum Tilt Angle (degrees)
Maximum Tilt Angle (degrees)
Nominal CS
2.7
Imaging Mode
BRIGHT FIELD
Specimen Holder Model
FEI TITAN KRIOS AUTOGRID HOLDER
Nominal Magnification
105000
Calibrated Magnification
Source
FIELD EMISSION GUN
Acceleration Voltage (kV)
300
Imaging Details
EM Software
Task
Software Package
Version
PARTICLE SELECTION
cryoSPARC
3.3.2
IMAGE ACQUISITION
SerialEM
CTF CORRECTION
cryoSPARC
3.3.2
MODEL FITTING
UCSF Chimera
1.16
MODEL FITTING
Coot
MODEL REFINEMENT
Coot
MODEL REFINEMENT
PHENIX
1.20.1-4487
INITIAL EULER ASSIGNMENT
cryoSPARC
3.3.2
FINAL EULER ASSIGNMENT
cryoSPARC
3.3.2
CLASSIFICATION
cryoSPARC
3.3.2
RECONSTRUCTION
cryoSPARC
3.3.2
Image Processing
CTF Correction Type
CTF Correction Details
Number of Particles Selected
Particle Selection Details
PHASE FLIPPING AND AMPLITUDE CORRECTION
Patch CTF
4802706
Good 2D class averages generated from ~1,000 manually picked particles served as templates for automatic particle picking.