ELECTRON MICROSCOPY
| Sample |
|---|
| HIV-2 capsid protein assembled into a lattice via liposome templating and then bound with Nup153 peptide. |
| Sample Components |
| HIV-2 capsid protein |
| Nup153 peptide |
| Specimen Preparation | |
|---|---|
| Sample Aggregation State | PARTICLE |
| Vitrification Instrument | FEI VITROBOT MARK IV |
| Cryogen Name | ETHANE |
| Sample Vitrification Details | Grids were dual-side blotted with blot force 0 for 5.5 sec before plunge freezing in liquid ethane. |
| 3D Reconstruction | |
|---|---|
| Reconstruction Method | SINGLE PARTICLE |
| Number of Particles | 1494376 |
| Reported Resolution (Å) | 2.99 |
| Resolution Method | FSC 0.143 CUT-OFF |
| Other Details | |
| Refinement Type | |
| Symmetry Type | POINT |
| Point Symmetry | C6 |
| Map-Model Fitting and Refinement | |||||
|---|---|---|---|---|---|
| Id | 1 | ||||
| Refinement Space | REAL | ||||
| Refinement Protocol | OTHER | ||||
| Refinement Target | Cross-correlation coefficient | ||||
| Overall B Value | |||||
| Fitting Procedure | |||||
| Details | The HIV-2 CA pentamer chain derived from micelle-templated icosahedra described in this publication was used as an initial model for fitting. Flexible ... | ||||
| Data Acquisition | |||||||||
|---|---|---|---|---|---|---|---|---|---|
| Detector Type | GATAN K3 (6k x 4k) | ||||||||
| Electron Dose (electrons/Å**2) | 50 | ||||||||
| Imaging Experiment | 1 |
|---|---|
| Date of Experiment | |
| Temperature (Kelvin) | |
| Microscope Model | FEI TITAN KRIOS |
| Minimum Defocus (nm) | 800 |
| Maximum Defocus (nm) | 2000 |
| Minimum Tilt Angle (degrees) | |
| Maximum Tilt Angle (degrees) | |
| Nominal CS | 2.7 |
| Imaging Mode | BRIGHT FIELD |
| Specimen Holder Model | FEI TITAN KRIOS AUTOGRID HOLDER |
| Nominal Magnification | 81000 |
| Calibrated Magnification | |
| Source | FIELD EMISSION GUN |
| Acceleration Voltage (kV) | 300 |
| Imaging Details |
| EM Software | ||
|---|---|---|
| Task | Software Package | Version |
| PARTICLE SELECTION | cryoSPARC | |
| IMAGE ACQUISITION | SerialEM | |
| CTF CORRECTION | cryoSPARC | |
| MODEL FITTING | Coot | |
| MODEL REFINEMENT | Coot | |
| INITIAL EULER ASSIGNMENT | cryoSPARC | |
| FINAL EULER ASSIGNMENT | cryoSPARC | |
| CLASSIFICATION | cryoSPARC | |
| RECONSTRUCTION | cryoSPARC | |
| Image Processing | ||||
|---|---|---|---|---|
| CTF Correction Type | CTF Correction Details | Number of Particles Selected | Particle Selection Details | |
| PHASE FLIPPING AND AMPLITUDE CORRECTION | 11931864 | |||














