☰ Navigation Tabs
G115 gamma delta TCR/CD3 complex bound by OKT3 Fab
Refinement RMS Deviations Key Refinement Restraint Deviation f_dihedral_angle_d 15.4345 f_angle_d 0.6918 f_chiral_restr 0.0453 f_bond_d 0.0039 f_plane_restr 0.0032
Sample G115 gamma delta TCR/CD3 complex bound by OKT3 Fab
Specimen Preparation Sample Aggregation State PARTICLE Vitrification Instrument Cryogen Name ETHANE Sample Vitrification Details
3D Reconstruction Reconstruction Method SINGLE PARTICLE Number of Particles 290758 Reported Resolution (Å) 3.27 Resolution Method FSC 0.143 CUT-OFF Other Details Refinement Type Symmetry Type POINT
Map-Model Fitting and Refinement Id 1 Refinement Space Refinement Protocol Refinement Target Overall B Value Fitting Procedure Details
Data Acquisition Detector Type GATAN K3 BIOQUANTUM (6k x 4k) Electron Dose (electrons/Å**2) 50
Imaging Experiment 1 Date of Experiment Temperature (Kelvin) Microscope Model FEI TITAN KRIOS Minimum Defocus (nm) 1000 Maximum Defocus (nm) 2200 Minimum Tilt Angle (degrees) Maximum Tilt Angle (degrees) Nominal CS Imaging Mode BRIGHT FIELD Specimen Holder Model Nominal Magnification Calibrated Magnification Source FIELD EMISSION GUN Acceleration Voltage (kV) 300 Imaging Details
EM Software Task Software Package Version MODEL REFINEMENT PHENIX 1.21.1_5286
Image Processing CTF Correction Type CTF Correction Details Number of Particles Selected Particle Selection Details PHASE FLIPPING AND AMPLITUDE CORRECTION