SOLUTION NMR
NMR Experiment
ExperimentTypeSample ContentsSolventIonic StrengthpHPressureTemperature (K)Spectrometer
12D 1H-15N HSQC0.6 mM [U-100% 13C; U-100% 15N] PTN, 10 % v/v D2O, 10 mM MES, 150 mM sodium chloride90% H2O/10% D2O0.156.0ambient298
23D HNCACB0.6 mM [U-100% 13C; U-100% 15N] PTN, 10 % v/v D2O, 10 mM MES, 150 mM sodium chloride90% H2O/10% D2O0.156.0ambient298
33D CBCA(CO)NH0.6 mM [U-100% 13C; U-100% 15N] PTN, 10 % v/v D2O, 10 mM MES, 150 mM sodium chloride90% H2O/10% D2O0.156.0ambient298
43D H(CCO)NH0.6 mM [U-100% 13C; U-100% 15N] PTN, 10 % v/v D2O, 10 mM MES, 150 mM sodium chloride90% H2O/10% D2O0.156.0ambient298
53D HCCH-TOCSY0.6 mM [U-100% 13C; U-100% 15N] PTN, 10 % v/v D2O, 10 mM MES, 150 mM sodium chloride90% H2O/10% D2O0.156.0ambient298
63D 1H-15N NOESY0.6 mM [U-100% 13C; U-100% 15N] PTN, 10 % v/v D2O, 10 mM MES, 150 mM sodium chloride90% H2O/10% D2O0.156.0ambient298
73D 1H-13C NOESY0.6 mM [U-100% 13C; U-100% 15N] PTN, 10 % v/v D2O, 10 mM MES, 150 mM sodium chloride90% H2O/10% D2O0.156.0ambient298
83D 1H-13C NOESY0.6 mM [U-100% 13C; U-100% 15N] PTN, 10 % v/v D2O, 10 mM MES, 150 mM sodium chloride90% H2O/10% D2O0.156.0ambient298
NMR Spectrometer Information
SpectrometerManufacturerModelField Strength
1BrukerAVANCE600
2VarianINOVA800
NMR Refinement
MethodDetailsSoftware
simulated annealingwater refinement with the default protocolNMRPipe
NMR Ensemble Information
Conformer Selection Criteriastructures with the least restraint violations
Conformers Calculated Total Number100
Conformers Submitted Total Number10
Representative Model1 (fewest violations)
Computation: NMR Software
#ClassificationVersionSoftware NameAuthor
1processingNMRPipeDelaglio, Grzesiek, Vuister, Zhu, Pfeifer and Bax
2data analysisNMRViewJohnson, One Moon Scientific
3structure solutionCYANAGuntert, Mumenthaler and Wuthrich
4refinementX-PLOR NIHSchwieters, Kuszewski, Tjandra and Clore