Electron crystallographic structure of lens Aquaporin-0 (AQP0) (lens MIP) in E. coli polar lipids
ELECTRON CRYSTALLOGRAPHY
Starting Model(s)
Initial Refinement Model(s) | |||
---|---|---|---|
Type | Source | Accession Code | Details |
experimental model | PDB | 2B6O | PDB entry 2B6O |
Crystallization
Crystalization Experiments | ||||
---|---|---|---|---|
ID | Method | pH | Temperature | Details |
1 | MICRODIALYSIS | 6 | 300 | 100 mM NaCl, 50mM MgCl2, 10mM MES pH 6.0, MICRODIALYSIS, temperature 300K |
Crystal Data
Unit Cell | |
---|---|
Length ( Å ) | Angle ( ˚ ) |
a = 65.5 | α = 90 |
b = 65.5 | β = 90 |
c = 200 | γ = 90 |
Symmetry | |
---|---|
Space Group | P 4 2 2 |
Diffraction
Diffraction Experiment | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
ID # | Crystal ID | Scattering Type | Data Collection Temperature | Detector | Detector Type | Details | Collection Date | Monochromator | Protocol | |||||
1 | 1 | 279 | CCD | Gatan | 2009-02-24 |
Radiation Source | |||||
---|---|---|---|---|---|
ID # | Source | Type | Wavelength List | Synchrotron Site | Beamline |
1 | ELECTRON MICROSCOPE | OTHER |
Data Collection
Overall | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
ID # | Resolution (High) | Resolution (Low) | Percent Possible (Observed) | R Merge I (Observed) | R Sym I (Observed) | Net I Over Average Sigma (I) | Redundancy | Number Reflections (All) | Number Reflections (Observed) | Observed Criterion Sigma (F) | Observed Criterion Sigma (I) | B (Isotropic) From Wilson Plot | |||||||
1 | 2.5 | 15.89 | 92.3 | 0.226 | 0.189 | 8.1 | 14417 | 14417 | 14.9 |
Highest Resolution Shell | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
ID # | Resolution (High) | Resolution (Low) | Percent Possible (All) | Percent Possible (Observed) | Mean I Over Sigma (Observed) | Redundancy | Number Unique Reflections (All) | ||||||||||||
1 | 2.5 | 2.66 | 83.7 | 4 | 1935 |
Refinement
Statistics | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Diffraction ID | Structure Solution Method | Cross Validation method | Starting model | Resolution (High) | Resolution (Low) | Number Reflections (All) | Number Reflections (Observed) | Number Reflections (R-Free) | Percent Reflections (Observed) | R-Factor (All) | R-Factor (Observed) | R-Work (Depositor) | R-Work (DCC) | R-Free (Depositor) | R-Free (DCC) | R-Free Selection Details | Mean Isotropic B | ||
ELECTRON CRYSTALLOGRAPHY | MOLECULAR REPLACEMENT | THROUGHOUT | PDB entry 2B6O | 2.5 | 15.89 | 14254 | 14254 | 1453 | 89.8 | 0.25 | 0.25 | 0.25 | 0.2656 | 0.284 | 0.2973 | RANDOM | 48.6 |
Temperature Factor Modeling | ||||||
---|---|---|---|---|---|---|
Anisotropic B[1][1] | Anisotropic B[2][2] | Anisotropic B[3][3] | ||||
-9.84 | -9.84 | 19.68 |
RMS Deviations | |
---|---|
Key | Refinement Restraint Deviation |
c_dihedral_angle_d | 19.7 |
c_improper_angle_d | 5.98 |
c_angle_deg | 1.8 |
c_bond_d | 0.008 |
Non-Hydrogen Atoms Used in Refinement | |
---|---|
Non-Hydrogen Atoms | Number |
Protein Atoms | 1668 |
Nucleic Acid Atoms | |
Solvent Atoms | 8 |
Heterogen Atoms | 273 |
Software
Software | |
---|---|
Software Name | Purpose |
Gatan | data collection |
PHASER | phasing |
CNS | refinement |
Sample |
---|
lens Aquaporin 0 |
Specimen Preparation | |
---|---|
Sample Aggregation State | 2D ARRAY |
3D Reconstruction | |
---|---|
Reconstruction Method | CRYSTALLOGRAPHY |
Data Acquisition | |||||||||
---|---|---|---|---|---|---|---|---|---|
Detector Type | GENERIC GATAN (4k x 4k) | ||||||||
Electron Dose (electrons/Å**2) |
Imaging Experiment | 1 |
---|---|
Date of Experiment | |
Temperature (Kelvin) | |
Microscope Model | FEI POLARA 300 |
Minimum Defocus (nm) | |
Maximum Defocus (nm) | |
Minimum Tilt Angle (degrees) | |
Maximum Tilt Angle (degrees) | |
Nominal CS | |
Imaging Mode | DIFFRACTION |
Specimen Holder Model | |
Nominal Magnification | |
Calibrated Magnification | |
Source | FIELD EMISSION GUN |
Acceleration Voltage (kV) | 300 |
Imaging Details |