487D
SEVEN RIBOSOMAL PROTEINS FITTED TO A CRYO-ELECTRON MICROSCOPIC MAP OF THE LARGE 50S SUBUNIT AT 7.5 ANGSTROMS RESOLUTION
ELECTRON MICROSCOPY
Sample |
---|
LARGE 50S RIBOSOMAL SUBUNIT |
Specimen Preparation | |
---|---|
Sample Aggregation State | PARTICLE |
3D Reconstruction | |
---|---|
Reconstruction Method | SINGLE PARTICLE |
Number of Particles | 16000 |
Reported Resolution (Å) | 7.5 |
Resolution Method | FSC 3 SIGMA CUT-OFF |
Other Details | |
Refinement Type | |
Symmetry Type | POINT |
Point Symmetry | C1 |
Map-Model Fitting and Refinement | |||||
---|---|---|---|---|---|
Id | 1 (1CSV, 1CSX, 1CSW) | ||||
Refinement Space | REAL | ||||
Refinement Protocol | |||||
Refinement Target | |||||
Overall B Value | |||||
Fitting Procedure | |||||
Details | DETAILS--OTHER REFINEMENT REMARKS- CRYO-EM RECONSTRUCTION THIS FILE HAS BEEN GENERATED BY THE USE OF ALL RELEVANT BIOCHEMICAL CONSTRAINTS AND THE CO ... |
Data Acquisition | |||||||||
---|---|---|---|---|---|---|---|---|---|
Detector Type | GENERIC FILM | ||||||||
Electron Dose (electrons/Å**2) |
Imaging Experiment | 1 |
---|---|
Date of Experiment | |
Temperature (Kelvin) | |
Microscope Model | FEI/PHILIPS CM200FEG |
Minimum Defocus (nm) | 1000 |
Maximum Defocus (nm) | 2000 |
Minimum Tilt Angle (degrees) | |
Maximum Tilt Angle (degrees) | |
Nominal CS | |
Imaging Mode | BRIGHT FIELD |
Specimen Holder Model | GATAN LIQUID NITROGEN |
Nominal Magnification | 38000 |
Calibrated Magnification | |
Source | FIELD EMISSION GUN |
Acceleration Voltage (kV) | 200 |
Imaging Details | from Structure 1999 citation |