SOLUTION NMR
NMR Experiment
ExperimentTypeSample ContentsSolventIonic StrengthpHPressureTemperature (K)Spectrometer
13D HNCO50 mM potassium phosphate, 50 mM potassium chloride, 10 mM DTT94% H2O/6% D2O100 mM7.01 atm298Bruker AVANCE II 700
23D HN(CA)CO50 mM potassium phosphate, 50 mM potassium chloride, 10 mM DTT94% H2O/6% D2O100 mM7.01 atm298Bruker AVANCE II 700
33D HNCA50 mM potassium phosphate, 50 mM potassium chloride, 10 mM DTT94% H2O/6% D2O100 mM7.01 atm298Bruker AVANCE II 700
43D HN(CO)CA50 mM potassium phosphate, 50 mM potassium chloride, 10 mM DTT94% H2O/6% D2O100 mM7.01 atm298Bruker AVANCE II 700
53D CBCA(CO)NH50 mM potassium phosphate, 50 mM potassium chloride, 10 mM DTT94% H2O/6% D2O100 mM7.01 atm298Bruker AVANCE II 700
63D HNCACB50 mM potassium phosphate, 50 mM potassium chloride, 10 mM DTT94% H2O/6% D2O100 mM7.01 atm298Bruker AVANCE II 700
73D C(CO)NH50 mM potassium phosphate, 50 mM potassium chloride, 10 mM DTT94% H2O/6% D2O100 mM7.01 atm298Bruker AVANCE II 700
83D HBHA(CO)NH50 mM potassium phosphate, 50 mM potassium chloride, 10 mM DTT94% H2O/6% D2O100 mM7.01 atm298Bruker AVANCE II 700
93D HCCH-TOCSY50 mM potassium phosphate, 50 mM potassium chloride, 10 mM DTT94% H2O/6% D2O100 mM7.01 atm298Bruker AVANCE II 700
103D CCH-TOCSY50 mM potassium phosphate, 50 mM potassium chloride, 10 mM DTT94% H2O/6% D2O100 mM7.01 atm298Bruker AVANCE II 700
113D HCCH-COSY50 mM potassium phosphate, 50 mM potassium chloride, 10 mM DTT94% H2O/6% D2O100 mM7.01 atm298Bruker AVANCE II 700
123D 1H-15N NOESY50 mM potassium phosphate, 50 mM potassium chloride, 10 mM DTT94% H2O/6% D2O100 mM7.01 atm298Bruker AVANCE II 700
133D 1H-13C NOESY50 mM potassium phosphate, 50 mM potassium chloride, 10 mM DTT94% H2O/6% D2O100 mM7.01 atm298Bruker AVANCE II 700
142D 1H-15N HSQC50 mM potassium phosphate, 50 mM potassium chloride, 10 mM DTT94% H2O/6% D2O100 mM7.01 atm298Bruker AVANCE II 700
152D 1H-13C HSQC50 mM potassium phosphate, 50 mM potassium chloride, 10 mM DTT94% H2O/6% D2O100 mM7.01 atm298Bruker AVANCE II 700
NMR Spectrometer Information
SpectrometerManufacturerModelField Strength
1BrukerAVANCE II700
NMR Refinement
MethodDetailsSoftware
simulated annealingX-PLOR NIH
NMR Ensemble Information
Conformer Selection Criteriastructures with the lowest energy
Conformers Calculated Total Number50
Conformers Submitted Total Number10
Representative Model1 (lowest energy)
Computation: NMR Software
#ClassificationVersionSoftware NameAuthor
1collectionTopSpinBruker Biospin
2processingNMRPipeDelaglio, Grzesiek, Vuister, Zhu, Pfeifer and Bax
3data analysisMAGROKobayashi, N.
4data analysisNMRViewJohnson, One Moon Scientific
5structure calculationCYANAGuntert, Mumenthaler and Wuthrich
6refinementX-PLOR NIHSchwieters, Kuszewski, Tjandra and Clore