6M71

SARS-Cov-2 RNA-dependent RNA polymerase in complex with cofactors


ELECTRON MICROSCOPY

Refinement

RMS Deviations
KeyRefinement Restraint Deviation
f_dihedral_angle_d2.485
f_angle_d0.482
f_chiral_restr0.041
f_plane_restr0.004
f_bond_d0.003
Sample
SARS-CoV-2 RNA-dependent RNA polymerase in complex with cofactors
Specimen Preparation
Sample Aggregation StatePARTICLE
Vitrification InstrumentFEI VITROBOT MARK II
Cryogen NameETHANE
Sample Vitrification Detailsblot for 3 seconds before plunging.
3D Reconstruction
Reconstruction MethodSINGLE PARTICLE
Number of Particles110176
Reported Resolution (Å)2.9
Resolution MethodFSC 0.143 CUT-OFF
Other DetailsThe particle set was used to perform homogeneous refinement, yielding a resolution of 3.1-angstrom. After local refinement, the final resolution reach ...The particle set was used to perform homogeneous refinement, yielding a resolution of 3.1-angstrom. After local refinement, the final resolution reached 2.9-angstrom.
Refinement Type
Symmetry TypePOINT
Point SymmetryC1
Map-Model Fitting and Refinement
Id1 (6NUR, 6NUR, 6NUR, 6NUR)
Refinement SpaceREAL
Refinement ProtocolRIGID BODY FIT
Refinement Targetcorrelation coefficient
Overall B Value65
Fitting Procedure
DetailsAfter the corresponding amino acids were replaced with those from 2019-nCoV, the model was manually built in Coot with the guidance of the cryo-EM map ...After the corresponding amino acids were replaced with those from 2019-nCoV, the model was manually built in Coot with the guidance of the cryo-EM map, and in combination with real space refinement with Phenix.
Data Acquisition
Detector TypeGATAN K2 QUANTUM (4k x 4k)
Electron Dose (electrons/Å**2)60
Imaging Experiment1
Date of Experiment
Temperature (Kelvin)
Microscope ModelFEI TITAN KRIOS
Minimum Defocus (nm)1000
Maximum Defocus (nm)2000
Minimum Tilt Angle (degrees)
Maximum Tilt Angle (degrees)
Nominal CS2.7
Imaging ModeBRIGHT FIELD
Specimen Holder ModelFEI TITAN KRIOS AUTOGRID HOLDER
Nominal Magnification165000
Calibrated Magnification
SourceFIELD EMISSION GUN
Acceleration Voltage (kV)300
Imaging DetailsPreliminary grid screening was performed manually.
EM Software
TaskSoftware PackageVersion
IMAGE ACQUISITIONSerialEM3-7-3
CTF CORRECTIONcryoSPARC2.9.1
MODEL FITTINGUCSF Chimera1.14
MODEL REFINEMENTPHENIX1.16
INITIAL EULER ASSIGNMENTcryoSPARC2.9.1
FINAL EULER ASSIGNMENTcryoSPARC2.9.1
CLASSIFICATIONcryoSPARC2.9.1
RECONSTRUCTIONcryoSPARC2.9.1
Image Processing
CTF Correction TypeCTF Correction DetailsNumber of Particles SelectedParticle Selection Details
PHASE FLIPPING AND AMPLITUDE CORRECTIONThe CTF correction was done by patch CTF correction.2334248The particles were automatically selected using blob pickier (diameter range from 100 angstroms to 150 angstroms)