SOLUTION NMR
NMR Experiment
ExperimentTypeSample ContentsSolventIonic StrengthpHPressureTemperature (K)Spectrometer
12D 1H-15N HSQC0.5 mM [U-99% 13C; U-99% 15N] VEK50RH1/AA, 2 ug/mL DSS, 1 ug/mL DTT, 20 mM [U-2H] Bis-Tris-d1993% H2O/7% D2O20 mM6.81 atm298Bruker AVANCE II 800
22D NOESY0.5 mM [U-99% 13C; U-99% 15N] VEK50RH1/AA, 2 ug/mL DSS, 1 ug/mL DTT, 20 mM [U-2H] Bis-Tris-d1993% H2O/7% D2O20 mM6.81 atm298Bruker AVANCE II 800
33D CBCA(CO)NH0.5 mM [U-99% 13C; U-99% 15N] VEK50RH1/AA, 2 ug/mL DSS, 1 ug/mL DTT, 20 mM [U-2H] Bis-Tris-d1993% H2O/7% D2O20 mM6.81 atm298Bruker AVANCE II 800
43D C(CO)NH0.5 mM [U-99% 13C; U-99% 15N] VEK50RH1/AA, 2 ug/mL DSS, 1 ug/mL DTT, 20 mM [U-2H] Bis-Tris-d1993% H2O/7% D2O20 mM6.81 atm298Bruker AVANCE II 800
53D HNCO0.5 mM [U-99% 13C; U-99% 15N] VEK50RH1/AA, 2 ug/mL DSS, 1 ug/mL DTT, 20 mM [U-2H] Bis-Tris-d1993% H2O/7% D2O20 mM6.81 atm298Bruker AVANCE II 800
63D HNCA0.5 mM [U-99% 13C; U-99% 15N] VEK50RH1/AA, 2 ug/mL DSS, 1 ug/mL DTT, 20 mM [U-2H] Bis-Tris-d1993% H2O/7% D2O20 mM6.81 atm298Bruker AVANCE II 800
83D HNCACB0.5 mM [U-99% 13C; U-99% 15N] VEK50RH1/AA, 2 ug/mL DSS, 1 ug/mL DTT, 20 mM [U-2H] Bis-Tris-d1993% H2O/7% D2O20 mM6.81 atm298Bruker AVANCE II 800
NMR Spectrometer Information
SpectrometerManufacturerModelField Strength
1BrukerAVANCE II800
NMR Refinement
MethodDetailsSoftware
simulated annealingX-PLOR NIH
NMR Ensemble Information
Conformer Selection Criteriastructures with the least restraint violations
Conformers Calculated Total Number200
Conformers Submitted Total Number20
Representative Model1 (fewest violations)
Computation: NMR Software
#ClassificationVersionSoftware NameAuthor
1collectionTopSpinBruker Biospin
2data analysisSparkyGoddard
3chemical shift assignmentSparkyGoddard
4structure calculationCS-ROSETTAShen, Vernon, Baker and Bax
5refinementX-PLOR NIHSchwieters, Kuszewski, Tjandra and Clore
6structure calculationX-PLOR NIHSchwieters, Kuszewski, Tjandra and Clore