☰ Navigation Tabs
Structure of the C-terminal Domain of RAGE and Its Inhibitor
NMR Experiment Experiment Type Sample Contents Solvent Ionic Strength pH Pressure Temperature (K) Spectrometer 1 3D HNCA 300 uM [U-100% 13C; U-100% 15N] C-terminal RAGE 90% H2O/10% D2O 10 mM 7 1 atm 298 Bruker AVANCE 600 2 3D 1H-15N NOESY 300 uM [U-100% 13C; U-100% 15N] C-terminal RAGE 90% H2O/10% D2O 10 mM 7 1 atm 298 Bruker AVANCE 600 3 3D 1H-13C NOESY aliphatic 300 uM [U-100% 13C; U-100% 15N] C-terminal RAGE 90% H2O/10% D2O 10 mM 7 1 atm 298 Bruker AVANCE 600 4 3D HNCACB 300 uM [U-100% 13C; U-100% 15N] C-terminal RAGE 90% H2O/10% D2O 10 mM 7 1 atm 298 Bruker AVANCE 600 5 3D HN(CO)CA 300 uM [U-100% 13C; U-100% 15N] C-terminal RAGE 90% H2O/10% D2O 10 mM 7 1 atm 298 Bruker AVANCE 600 6 3D 1H-15N TOCSY 300 uM [U-100% 13C; U-100% 15N] C-terminal RAGE 90% H2O/10% D2O 10 mM 7 1 atm 298 Bruker AVANCE 600 7 3D 1H-13C NOESY aromatic 300 uM [U-100% 13C; U-100% 15N] C-terminal RAGE 90% H2O/10% D2O 10 mM 7 1 atm 298 Bruker AVANCE 600 8 3D CBCA(CO)NH 300 uM [U-100% 13C; U-100% 15N] C-terminal RAGE 90% H2O/10% D2O 10 mM 7 1 atm 298 Bruker AVANCE 600 9 3D HCCCONH 300 uM [U-100% 13C; U-100% 15N] C-terminal RAGE 90% H2O/10% D2O 10 mM 7 1 atm 298 Bruker AVANCE 600 10 3D HCCH-TOCSY 300 uM [U-100% 13C; U-100% 15N] C-terminal RAGE 90% H2O/10% D2O 10 mM 7 1 atm 298 Bruker AVANCE 600
NMR Spectrometer Information Spectrometer Manufacturer Model Field Strength 1 Bruker AVANCE 600
NMR Refinement Method Details Software simulated annealing CYANA
NMR Ensemble Information Conformer Selection Criteria structures with the least restraint violations Conformers Calculated Total Number 200 Conformers Submitted Total Number 20 Representative Model 1 (lowest energy)
Computation: NMR Software # Classification Version Software Name Author 1 refinement CYANA 3.98.5 Guntert P. 2 chemical shift assignment CARA 1.9.1.7 Keller and Wuthrich 4 peak picking CARA 1.9.1.7 Keller and Wuthrich 3 structure calculation CYANA 3.98.5 Guntert P.