6Y92

Structure of full-length CD20 in complex with Ofatumumab Fab


ELECTRON MICROSCOPY

Refinement

RMS Deviations
KeyRefinement Restraint Deviation
f_dihedral_angle_d19.553
f_angle_d0.68
f_chiral_restr0.042
f_plane_restr0.004
f_bond_d0.003
Sample
Full-length human antigen CD20 in complex with Ofatumumab Fab
Sample Components
Full-length human CD20
Ofatumumab Fab
Specimen Preparation
Sample Aggregation StatePARTICLE
Vitrification InstrumentFEI VITROBOT MARK IV
Cryogen NameETHANE
Sample Vitrification Details
3D Reconstruction
Reconstruction MethodSINGLE PARTICLE
Number of Particles99146
Reported Resolution (Å)4.73
Resolution MethodFSC 0.143 CUT-OFF
Other Details
Refinement Type
Symmetry TypePOINT
Point SymmetryC2
Map-Model Fitting and Refinement
Id1 (3GIZ, 3GIZ)
Refinement SpaceREAL
Refinement ProtocolRIGID BODY FIT
Refinement Target
Overall B Value
Fitting Procedure
Details
Data Acquisition
Detector TypeFEI FALCON III (4k x 4k)
Electron Dose (electrons/Å**2)40
Imaging Experiment1
Date of Experiment
Temperature (Kelvin)
Microscope ModelTFS GLACIOS
Minimum Defocus (nm)
Maximum Defocus (nm)
Minimum Tilt Angle (degrees)
Maximum Tilt Angle (degrees)
Nominal CS2.7
Imaging ModeBRIGHT FIELD
Specimen Holder Model
Nominal Magnification
Calibrated Magnification
SourceFIELD EMISSION GUN
Acceleration Voltage (kV)200
Imaging Details
EM Software
TaskSoftware PackageVersion
IMAGE ACQUISITIONEPU
CTF CORRECTIONGctf1.06
MODEL FITTINGUCSF Chimera1.13.1
MODEL FITTINGCoot0.8.9.2
INITIAL EULER ASSIGNMENTcryoSPARC2.14.2
FINAL EULER ASSIGNMENTcryoSPARC2.14.2
CLASSIFICATIONcryoSPARC2.14.2
RECONSTRUCTIONcryoSPARC2.14.2
MODEL REFINEMENTPHENIX1.17.1
Image Processing
CTF Correction TypeCTF Correction DetailsNumber of Particles SelectedParticle Selection Details
PHASE FLIPPING AND AMPLITUDE CORRECTION919699