6ZXL
Fully-loaded anthrax lethal toxin in its heptameric pre-pore state and PA7LF(2+1A) arrangement
ELECTRON MICROSCOPY
Starting Model(s)
Initial Refinement Model(s) | |||
---|---|---|---|
Type | Source | Accession Code | Details |
experimental model | PDB | 6ZXK |
Refinement
RMS Deviations | |
---|---|
Key | Refinement Restraint Deviation |
f_dihedral_angle_d | 5.395 |
f_angle_d | 1.345 |
f_chiral_restr | 0.066 |
f_bond_d | 0.013 |
f_plane_restr | 0.008 |
Sample |
---|
Fully-loaded anthrax lethal toxin in its heptameric pre-pore state and PA7LF(2+1A) arrangement |
Sample Components |
Protective antigen |
Lethal factor |
Specimen Preparation | |
---|---|
Sample Aggregation State | PARTICLE |
Vitrification Instrument | GATAN CRYOPLUNGE 3 |
Cryogen Name | ETHANE |
Sample Vitrification Details | 4 uL sample was applied to grid (with 2 nm additional carbon layer) and incubated for 45 s prior blotting. |
3D Reconstruction | |
---|---|
Reconstruction Method | SINGLE PARTICLE |
Number of Particles | 44000 |
Reported Resolution (Å) | 4.2 |
Resolution Method | FSC 0.143 CUT-OFF |
Other Details | |
Refinement Type | |
Symmetry Type | POINT |
Point Symmetry | C1 |
Map-Model Fitting and Refinement | |||||
---|---|---|---|---|---|
Id | 1 (6ZXK) | ||||
Refinement Space | |||||
Refinement Protocol | |||||
Refinement Target | |||||
Overall B Value | |||||
Fitting Procedure | |||||
Details | The previously generated PA7LF(2+1B) model (PDB:6ZXK) served as starting point and was placed into the density using rigid-body fit in Chimera. From t ... |
Data Acquisition | |||||||||
---|---|---|---|---|---|---|---|---|---|
Detector Type | GATAN K2 SUMMIT (4k x 4k) | ||||||||
Electron Dose (electrons/Å**2) | 74.4 |
Imaging Experiment | 1 |
---|---|
Date of Experiment | |
Temperature (Kelvin) | |
Microscope Model | FEI TITAN KRIOS |
Minimum Defocus (nm) | |
Maximum Defocus (nm) | |
Minimum Tilt Angle (degrees) | |
Maximum Tilt Angle (degrees) | |
Nominal CS | 2.7 |
Imaging Mode | BRIGHT FIELD |
Specimen Holder Model | FEI TITAN KRIOS AUTOGRID HOLDER |
Nominal Magnification | 130000 |
Calibrated Magnification | |
Source | FIELD EMISSION GUN |
Acceleration Voltage (kV) | 300 |
Imaging Details |
EM Software | ||
---|---|---|
Task | Software Package | Version |
PARTICLE SELECTION | crYOLO | |
IMAGE ACQUISITION | EPU | 1.10 |
CTF CORRECTION | SPHIRE | |
FINAL EULER ASSIGNMENT | SPHIRE | |
CLASSIFICATION | SPHIRE | |
RECONSTRUCTION | SPHIRE | |
MODEL REFINEMENT | PHENIX | 1.18.2 |
MODEL REFINEMENT | Coot | 0.8.9.1 |
Image Processing | ||||
---|---|---|---|---|
CTF Correction Type | CTF Correction Details | Number of Particles Selected | Particle Selection Details | |
PHASE FLIPPING AND AMPLITUDE CORRECTION | 382000 |