☰ Navigation Tabs
E. coli 70S ribosome complexed with tRNA_Ile2 bearing L34 and t6A37 in classical state
Starting Model(s) Initial Refinement Model(s) Type Source Accession Code Details experimental model PDB 7K00
Refinement RMS Deviations Key Refinement Restraint Deviation f_dihedral_angle_d 13.1118 f_angle_d 0.6566 f_chiral_restr 0.039 f_plane_restr 0.0055 f_bond_d 0.0042
Sample The complex of E. coli 70S ribosome with mRNA and A-, P- site tRNA Sample Components E. coli 70S ribosome A-, P- site tRNA mRNA
Specimen Preparation Sample Aggregation State PARTICLE Vitrification Instrument FEI VITROBOT MARK IV Cryogen Name ETHANE Sample Vitrification Details
3D Reconstruction Reconstruction Method SINGLE PARTICLE Number of Particles 201764 Reported Resolution (Å) 2.32 Resolution Method FSC 0.143 CUT-OFF Other Details Refinement Type Symmetry Type POINT
Map-Model Fitting and Refinement Id 1 (7K00) Refinement Space Refinement Protocol FLEXIBLE FIT Refinement Target Overall B Value Fitting Procedure Details
Data Acquisition Detector Type GATAN K3 (6k x 4k) Electron Dose (electrons/Å**2) 50
Imaging Experiment 1 Date of Experiment Temperature (Kelvin) Microscope Model FEI TITAN KRIOS Minimum Defocus (nm) 500 Maximum Defocus (nm) 2500 Minimum Tilt Angle (degrees) Maximum Tilt Angle (degrees) Nominal CS Imaging Mode BRIGHT FIELD Specimen Holder Model Nominal Magnification Calibrated Magnification Source FIELD EMISSION GUN Acceleration Voltage (kV) 300 Imaging Details
EM Software Task Software Package Version CTF CORRECTION RELION 3.1.3 MODEL FITTING UCSF Chimera 1.14 MODEL FITTING Coot 0.9.4.1 INITIAL EULER ASSIGNMENT RELION 3.1.3 FINAL EULER ASSIGNMENT RELION 3.1.3 CLASSIFICATION RELION 3.1.3 RECONSTRUCTION RELION 3.1.3 MODEL REFINEMENT PHENIX 1.19.2 MODEL REFINEMENT Coot 0.9.4.1
Image Processing CTF Correction Type CTF Correction Details Number of Particles Selected Particle Selection Details PHASE FLIPPING AND AMPLITUDE CORRECTION 851030