☰ Navigation Tabs
Amyloid-beta 40 type 2 filament from the leptomeninges of individual with Alzheimer's disease and cerebral amyloid angiopathy
Starting Model(s) Initial Refinement Model(s) Type Source Accession Code Details experimental model PDB 7Q4B
Refinement RMS Deviations Key Refinement Restraint Deviation r_long_range_B_other 15.005 r_long_range_B_refined 14.991 r_scangle_other 10.483 r_dihedral_angle_3_deg 8.991 r_mcangle_other 7.071 r_mcangle_it 7.054 r_scbond_it 6.259 r_scbond_other 6.249 r_dihedral_angle_1_deg 5.263 r_mcbond_it 4.574
Show All KeysRMS Deviations Key Refinement Restraint Deviation r_long_range_B_other 15.005 r_long_range_B_refined 14.991 r_scangle_other 10.483 r_dihedral_angle_3_deg 8.991 r_mcangle_other 7.071 r_mcangle_it 7.054 r_scbond_it 6.259 r_scbond_other 6.249 r_dihedral_angle_1_deg 5.263 r_mcbond_it 4.574 r_mcbond_other 4.544 r_dihedral_angle_2_deg 1.537 r_angle_refined_deg 1.079 r_angle_other_deg 0.53 r_chiral_restr 0.047 r_bond_refined_d 0.005 r_gen_planes_refined 0.004 r_gen_planes_other 0.002 r_bond_other_d 0.001 r_dihedral_angle_4_deg r_nbd_refined r_nbd_other r_nbtor_refined r_nbtor_other r_xyhbond_nbd_refined r_xyhbond_nbd_other r_metal_ion_refined r_metal_ion_other r_symmetry_vdw_refined r_symmetry_vdw_other r_symmetry_hbond_refined r_symmetry_hbond_other r_symmetry_metal_ion_refined r_symmetry_metal_ion_other r_scangle_it r_rigid_bond_restr r_sphericity_free r_sphericity_bonded
Hide All Keys
Specimen Preparation Sample Aggregation State FILAMENT Vitrification Instrument Cryogen Name ETHANE Sample Vitrification Details
3D Reconstruction Reconstruction Method HELICAL Number of Particles 81140 Reported Resolution (Å) 2.4 Resolution Method FSC 0.143 CUT-OFF Other Details Refinement Type Symmetry Type HELICAL Axial Symmetry C2 Axial Rise 4.87 Angular Rotation -0.78
Map-Model Fitting and Refinement Id 1 (7Q4B) Refinement Space Refinement Protocol Refinement Target Overall B Value Fitting Procedure Details
Data Acquisition Detector Type FEI FALCON IV (4k x 4k) Electron Dose (electrons/Å**2) 40
Imaging Experiment 1 Date of Experiment Temperature (Kelvin) Microscope Model FEI TITAN KRIOS Minimum Defocus (nm) 1000 Maximum Defocus (nm) 2400 Minimum Tilt Angle (degrees) Maximum Tilt Angle (degrees) Nominal CS Imaging Mode BRIGHT FIELD Specimen Holder Model Nominal Magnification Calibrated Magnification Source FIELD EMISSION GUN Acceleration Voltage (kV) 300 Imaging Details
EM Software Task Software Package Version PARTICLE SELECTION RELION 4.0 IMAGE ACQUISITION EPU CTF CORRECTION RELION MODEL FITTING Coot INITIAL EULER ASSIGNMENT RELION FINAL EULER ASSIGNMENT RELION CLASSIFICATION RELION RECONSTRUCTION RELION MODEL REFINEMENT REFMAC
Image Processing CTF Correction Type CTF Correction Details Number of Particles Selected Particle Selection Details PHASE FLIPPING AND AMPLITUDE CORRECTION